One platform for industrial data

All Kinds of Data. One Platform.

Live values from your PLCs, the files your dataloggers send, the forecasts built from all of it and, from 1.14.8, the checks your technicians record on site — stored together, with alarms, trends and reports in one place.

Download for WindowsSee how it works

Runs on your serveror our cloud

Five kinds of sources, one platform

Point at or tap a source to see where it shows up

SyncTide / Water network · LisbonLIVE 14:32

Flow — PLC vs datalogger24 h

  • OPC UA · FT-101
  • CSV · WL-07
  • forecast

Eventstoday

  1. CRITICALLow level below setpointRES-02 · PLC
  2. CLEAREDPressure back in rangePT-204 · MQTT · Sparkplug B
  3. LATEDatalogger file not receivedWL-11 · CSV · FTP
  4. VISITPump B inspection closed12 checks · 4 photos · signedNew in 1.14.8 — coming soon
  5. REPORTDaily report emailedPDF · 06:00
Sources
5 kinds
Tags
12 480
Stored today
3.1 M values
Open alarms
1

What happens to the data

Every value stored, watched, analysed and reported.

Alarms, trends and reports all read the same history. Pick a step to see a short example.

Each tag keeps its own history

New in 1.14.7 — coming soon

A value is stored when it moves past the tag's deadband, so the history holds the changes, not thousands of repeats.

  • Deadband per tag for Modbus, OPC UA and IEC 104
  • Report-by-exception with a heartbeat, so a flat signal never looks stale
  • Compression, and virtual tags computed from formulas
More on the Platform page
SyncTide / Tag FT-101 · historydeadband ±0.5 m³/h

Readings and stored valueslast hour

  • reading
  • stored
  • heartbeat
  • deadband
Readings
60
Stored
15
Heartbeat
15 min

Alarms that reach the right person

Rules with delays and hysteresis raise the alarm. Messaging sends it to whoever is on call and goes down the list until someone acknowledges.

  • Email, Telegram, WhatsApp and text messages through a cellular router
  • Communication-loss alarms when a source goes quiet
  • Forecast alarms before a limit is reached
More on the Platform page
SyncTide / Alarms · Water network · Lisbon1 OPEN

Alarm RES-0214:32

  1. CRITICALLow level below setpointRES-02 · 14:32:05
  2. MESSAGESent to the on-call technicianMessaging · Telegram · 14:32:06
  3. ACKAcknowledged by reply, escalation stoppedTelegram · 14:33:10

Telegram · on call

SyncTideCRITICAL · RES-02 Low level below setpointReply with "ack", "ok" or 👍 to acknowledge
ok

✓ Acknowledged

Trends, and what comes next

Put tags from any source on one chart in the Explorer, build dashboards, and compare sites with heatmaps and rankings.

  • Forecasts with a band, from the optional prediction module
  • Forecast alarms before the limit is reached
  • Dashboards, heatmaps and rankings
More on the Platform page
SyncTide / Explorer · FT-101FORECAST

Flow and forecast7 days + 2

  • FT-101
  • forecast
  • high limit

Events

  1. FORECASTForecast reaches the high limit in about 30 hforecast alarm · FT-101

Your letterhead on every PDF

New in 1.14.8 — coming soon

SyncTide draws the PDF itself, with the header you set up: logo, titles, dates including the first and last data, colours and footer. You preview it in the platform before it goes out.

  • Excel with your own layout
  • Schedules that send the report by email
  • Long reports run in the background
More on the Platform page
SyncTide / Reports · daily-flow.pdfPDF
Water network · LisbonDaily report

Flow and level, daily summary

19 Nov 2026 · first data 00:00 · last data 23:55

Volume12 840 m³
Max flow618 m³/h
Alarms2
HourFlow m³/hLevel m
00:004123.1
06:005382.8
12:006042.4
18:005772.6
Water network · Lisbon · page 1 of 1

Field work

Field work, recorded properly.

New in 1.14.8 — coming soon

Interventions puts the visit on the technician's phone. Each answer is saved as it is made, and the visit lands in the same history as your sensors.

See Interventions

InterventionsStep 1 of 5

Point at the asset's label

Pump B · Station 3QR ✓
New visit here

InterventionsStep 2 of 5

Monthly inspection

Pump B · Station 3

  • Seal without leaks
  • Vibration normal
  • Outlet pressurelimits 2–43.2 bar
  • Follow-up needed?No

InterventionsStep 3 of 5

Coupling guard refitted

Photo 1 of 2

InterventionsStep 4 of 5

Technician's signature

Sign above the line

InterventionsStep 5 of 5

Visit closed

Pump B · Station 3

12 checks · 2 photos · signed

Saved

Where it runs

Your server or our cloud.

The same platform either way. You choose where the data lives.

Your server

You install and run it, and the data stays on your network. Updates come from the interface, signed.

Windows installer
about 1.1 GB, everything included About 0.7 GB from 1.14.8
Linux (Docker)
on request
Download for Windows

Our cloud

We run it for you: datalogger files, MQTT and everything else, from alarms and Messaging to reports and forecasts (optional module).

PLCs in the cloud on request, through a secure tunnel.

Talk to us

Compare both on the Deployment page

Sizing

How much server?

Two answers give a first estimate. The full simulator has the rest.

4 cores · 8 GB memory · 210 GB disk

Assumes 3 years of history, every reading stored and 5 users.

Open the full simulator

In numbers

Measured, not promised.

  • 5

    kinds of sources — PLCs, MQTT, files, field work, formulas — in one history

    New in 1.14.8 — coming soon

    Source: same tags, same alarms

  • 90 000

    tags on one server, each with its own deadband

    New in 1.14.7 — coming soon

    Source: load test · 4 cores

  • 8.9 M

    historical points ingested in 20 minutes

    New in 1.14.7 — coming soon

    Source: 4-core VM · 1.14.7

  • 0.1 s

    to draw a PDF report with your letterhead

    New in 1.14.8 — coming soon

    Source: 1.14.8

Try it with your own data.

Install it on a Windows server, or let us run it in our cloud.